Enable Your Project with LED Drivers by eldoLED
Want this checklist?
Download Now!-
Controls Interface Supported: A Choice of Control Protocols to Cover Any Lighting Controls and Network Needs
Indoor
Industrial/ Demanding Environments
Outdoor
- Supports analog 0-10V OR D4i OR nLight OR SensorSwitch
- Programmable auxiliary outputs compatible with wide range of sensors and wired or wireless controls devices
- Supports analog 0-10V OR D4i OR nLight OR SensorSwitch
- Programmable auxiliary outputs compatible with wide range of sensors and wired or wireless controls devices.
- Supports analog 0-10V OR D4i OR Cell Connect OR DMX OR nLight OR SensorSwitch
- Programmable auxiliary outputs compatible with wide range of sensors and wired or wireless controls devices.
-
Dynamic Lighting - Tunable and Color: Ability to Adjust Color Temperature Over Customized Range. Smooth Transitions Between Intensity Levels and Color. Color Consistency in the Space
Indoor
Industrial/ Demanding Environments
Outdoor
- Supports Tunable White with DALI-2 OR DMX OR nLight
- Supports architainment RGBx with DMX
- Ability to adjust color temperature over customized range.
- Provides smooth transitions between intensity levels and color.
- Provides color consistency in the space
- Not Applicable
- Supports RGBx and RGBW with DMX
-
Consistent Behavior at Start Up/Shut Down: All Luminaires within a Space to have the Same Behavior at On and Off
Indoor
Industrial/ Demanding Environments
Outdoor
- No perceived timing difference at turn on, turn off and over dimming range
- Addresses requirements of California Title 24
- No perceived timing difference at turn on, turn off and over dimming range
- No perceived timing difference at turn on, turn off and over dimming range
-
No Electromagnetic Interference: No Unwanted Radiated or Conducted Interference in the Space
Indoor
Industrial/ Demanding Environments
Outdoor
- Complies with FCC title 47 part 15 class A & B
- Complies with FCC title 47 part 15 class A
- Complies with FCC title 47 part 15 class A
-
Surge & EFT Protection: Guard Against Failure
Indoor
Industrial/ Demanding Environments
Outdoor
- 2.5kV common and differential mode surge protection for indoor applications, complies with ANSI C62.41 Test Severity III - Cat A (ANSI C82.77-5-2017 Surge and Transient Standard)
- 6kV common and differential mode surge protection for industrial applications, complies with ANSI C62.41 Test Severity III - Cat B (ANSI C82.77-5-2017 Surge and Transient Standard)
- 6kV common and differential mode surge protection for outdoor applications, complies with ANSI C62.41 Test Severity III - Cat B (ANSI C82.77-5-2017 Surge and Transient Standard)